Class 4 Commercial Metal Roof Hail Ratings in North Texas

A Class 4 commercial metal roof hail rating means the panel passed the toughest level of the UL 2218 impact test without cracking or opening up, which is why owners in North Texas ask for it first. It does not mean the roof won't dent. Every metal roof we install is Class 4 impact rated under UL 2218. This page explains what the ratings test, what they don't, and what decides how a commercial metal roof actually holds up in a hailstorm.
  • TPO, PVC, modified bitumen, metal and coatings
  • Repairs, restorations and new roofs
  • NDL warranties typically 10 to 40 years, with manufacturer approval
  • American WeatherStar Approved Contractor
Illustration of a North Texas warehouse with a standing-seam metal roof and loading docks
Illustration

The ratings side by side

RatingHow it's testedWhat a pass means
UL 2218 Class 4A 2-inch steel ball dropped from 20 feet, twice on the same spot (Classes 1 to 3 use 1.25- to 1.75-inch balls from lower heights)No crack, split or opening in the panel or seam. Dents are allowed.
FM Class 1-MH (moderate hail)A 2-inch, 1.19-lb steel ball dropped from 81 inches, about 8 ft-lb of energy, 10 impacts on new and weathered samplesThe roof assembly resists that impact without failure
FM Class 1-SH (severe hail)The same ball from 141.5 inches, about 14 ft-lbA tougher assembly-level pass
FM Class 1-VSH (very severe hail)2-inch ice balls fired at 152 to 160 feet per second, which FM equates to hail up to about 2.5 inchesThe highest FM hail class; listed by assembly in FM's RoofNav

FM test details from FM Approvals, "New Tools Can Help Reduce Losses from Hail." FM rates whole roof assemblies, so the deck, insulation and attachment matter as much as the panel.

Dents vs leaks: what Class 4 does and doesn't promise

  • Functional damage is a crack, a punctured panel, a split seam or a broken fastener seal. That lets water in, and that's what the impact tests look for.
  • Cosmetic damage is a dent that doesn't let water in. A Class 4 panel can dent in big hail and still pass.
  • Some commercial property policies carry a cosmetic damage exclusion for metal roofs, so dents alone may not be covered. Read your policy before a storm, not after.
  • Coatings and paint finishes can crack at a deep dent over time. We note those spots in the inspection report.

What actually decides hail performance

FactorWhy it mattersWhat we do
GaugeThicker steel dents less. 24 gauge is thicker than 26.We form 24 or 26 gauge and price both where hail exposure justifies it
Profile and rib spacingWide flat pans show dents more than ribbed or striated panelsStriations or pencil ribs on standing seam; R-panel/PBR on metal buildings
What's under the panelPanels over a solid deck or cover board resist denting better than panels spanning open purlinsWe tell you which your building has and what changing it would take
Seams and lapsEnd laps and loose seams are where impacts turn into leaksOne-piece runs from our own roll formers, cut to each slope's length
Fasteners and trimExposed fastener washers and thin trim fail before the panelFastener pattern, washers and trim gauge specified in the bid

Hail in North Texas, by the numbers

  • NOAA lists 76 reports of hail 1.75 inches or larger in Wise County from 2005 through 2026, including 4.25-inch hail at Decatur on April 4, 2008 and 4.5-inch hail at Keeter on April 1, 2024.
  • NOAA logged 5-inch hail about a mile from the center of Mansfield on June 12, 2023, and 4.5-inch hail near Allen on March 24, 2019.
  • Within about 10 miles of Frisco NOAA lists 69 golf-ball-or-larger reports from 2016 through September 2026; Lewisville 51; Flower Mound 56; McKinney 62.

Source: NOAA NCEI Storm Events Database and NOAA SPC storm reports, as summarized on our city pages. A report shows where hail was seen, not whether a given roof was damaged.

Choosing a hail-tough commercial metal roof

  1. Ask for the rating in writing: the UL 2218 class of the exact panel and gauge, and the FM listing if your insurer or lender wants one
  2. Compare 24 and 26 gauge on the same bid
  3. Look at the substrate: open purlins, a solid deck, or a retrofit over an old flat roof (see metal retrofits)
  4. Check the slope the panel is rated for (see low-slope vs steep-slope metal)
  5. Read your policy for a cosmetic damage exclusion and ask your agent what a Class 4 roof changes

We form standing seam and R-panel/PBR in 24 or 26 gauge on our own roll formers, cut to the measured length of each run. Metal lead time is typically 1 to 2 weeks. Every metal roof we install is Class 4 impact rated under UL 2218.

After a hailstorm

We walk the roof, fly a drone for photos of areas that are hard to reach safely, and run drone thermal (infrared) scans that help show where water has gotten under the surface. Every inspection comes with a free digital photo report, so you see what we see. We separate dents from functional damage, photograph every elevation and measure hail marks on soft metals like vents and gutters, which tell us the hail size that hit your building. We document the damage with photos and measurements and can be on the roof when your adjuster inspects. We don't adjust or negotiate claims; you work the claim with your insurance company. Texas law requires you to pay your deductible, and we never waive or rebate it. In Texas you generally have 1 year from the date of loss to file; check your policy. See commercial hail claims.

Who we are

Owner Blake Snow has almost 40 years in the business, and the Snow family has been roofing in this market for 75 years. Snow Roofing started as a tier-one commercial company doing only large-scale work, including casino properties on the Mississippi Gulf Coast such as the Imperial Palace in 2006, right after Hurricane Katrina, before it expanded into residential. We've also done full exterior and interior rehabs on national-brand hotel properties around the DFW Metroplex. No job is too big or too small, Snow Roofing does them all. We're certified with GAF, CertainTeed, Owens Corning, Atlas, Johns Manville, Carlisle, Tropical Roofing Products, Mule-Hide and Enviroshake, and many other roof manufacturers. Manufacturer NDL (no-dollar-limit) warranties typically run from 10 to 40 years, depending on the manufacturer, the system, and manufacturer approval of the finished job. We do not promise a specific NDL term until that approval is in place. We offer same-day response in almost every case, and we answer leak and storm calls 24/7 at (817) 733-9228.

Related: commercial metal roofing · metal building re-roofs · ag and equestrian metal roofs · standing seam · R-panel and PBR.

Code sections and standards are summarized in plain English from the published documents. Your building official, the manufacturer's current specification and the warranty document have the final word.

Commercial warranty: a workmanship warranty from 10 years up to lifetime, depending on the job, plus manufacturer NDL (no-dollar-limit) warranties that typically run from 10 to 40 years, depending on the manufacturer, the system, and manufacturer approval of the finished job (we do not promise a specific NDL term until that approval is in place). Manufacturer coverage depends on the product and brand, and on the project qualifying for that manufacturer's program. We put the exact warranty for your roof in writing.

Certified, with almost 40 years in the business for owner Blake Snow, installing every major roofing brand, a family roofing legacy going back 75 years, and over $80 million in completed roofing projects. 5.0 stars on Google at all three of our offices.

Request a free inspection or call (817) 733-9228. Small repairs are welcome too.

Frequently asked questions

What does a Class 4 rating mean on a commercial metal roof?

It means the panel passed the highest level of the UL 2218 impact test, a 2-inch steel ball dropped from 20 feet twice on the same spot, without cracking or opening up. Dents are allowed under the test.

Will a Class 4 metal roof dent in hail?

It can. Class 4 is about keeping water out, not about staying dent-free. Thicker 24 gauge steel, ribbed or striated profiles and a solid substrate all reduce denting.

Is UL 2218 the same as an FM hail rating?

No. UL 2218 tests the roof covering with steel balls. FM Approvals rates whole roof assemblies as Class 1-MH, 1-SH or 1-VSH, and VSH uses 2-inch ice balls fired at high speed.

Does insurance cover dents on a metal roof?

It depends on your policy. Some commercial policies have a cosmetic damage exclusion for metal roofs. Read yours and ask your agent before a storm.

Are your metal roofs Class 4?

Yes. Every metal roof we install is Class 4 impact rated under UL 2218.

Should I choose 24 or 26 gauge for hail?

24 gauge is thicker and dents less. We price both on the same bid so you can weigh the cost against your hail exposure.

How fast can you respond to a leak?

Same-day response in almost every case, and we answer leak and storm calls 24/7 at (817) 733-9228.

Get a free estimate