Commercial corrugated metal

Corrugated Metal Roofing for Commercial Buildings

Corrugated metal, the classic wavy panel, is on plenty of older commercial and ag buildings in North Texas, and it's back in style on restaurants, venues and retail. Snow Roofing & Exteriors installs new corrugated panels, and also repairs, re-screws, coats and retrofits existing corrugated roofs. When a building is better served by a different profile, we can move it to PBR or standing seam formed on our own roll formers in 24 or 26 gauge.

Corrugated vs. the "ribbed" panels

Corrugated (round wave)PBR / R-panel (trapezoid rib)Standing seam
RibShallow, rounded; 7/8-in or 1/2-in depth are commonAbout 1-1/4 in, 12 in on centerRaised seam, hidden fasteners
CoverageOften about 32 in to 36 in, depending on profile36 in12 in to 18 in common
Minimum slopeVaries widely: some panels publish 1:12 with sealant at every lap, while makers commonly recommend 3:12 or steeperCommonly 1:12Down to about 1/4:12 for some mechanically seamed panels
FastenersExposed, in the valleys or on the crowns per the makerExposedHidden
LookRustic, industrial, historicUtilitarian metal buildingClean, architectural

Published values vary by manufacturer and panel. We confirm the exact panel's data before we quote.

Where commercial corrugated roofs leak

  • Fasteners: sun-dried washers and screws that have worked loose; on older roofs, nails instead of screws
  • End and side laps: shallow corrugations hold less water at the lap, so low slopes leak first here
  • Rust: at cut edges, laps and low spots, especially on older galvanized panels
  • Ridge and closures: missing or crushed closures let wind-driven rain and birds in
  • Hail: thin, older sheets dent and crack at the finish; light panels break

Install, repair, coat, retrofit or switch

ConditionWhat we usually recommend
Sheets sound, leaks at fasteners and lapsRe-fasten with new screws and washers, seal laps, replace closures and trim
Sheets sound, surface rust and aging finishRust treatment, then a restoration coating over repaired fasteners and laps
Rusted-through or thin sheets, structure goodRetrofit over the old roof, with no tear-off over the operation
Sheets worn out, corrugated look mattersNew corrugated panels in 24 or 26 gauge
Low slope with chronic lap leaks, look does not matterMove to PBR or mechanically seamed standing seam

We have hands-on experience with coating systems from American WeatherStar, EpoxyFlex, Carlisle and Tropical Roofing Products. We walk the roof, fly a drone for photos of areas that are hard to reach safely, and run drone thermal (infrared) scans that help show where water has gotten under the surface. Every inspection comes with a free digital photo report, so you see what we see.

Keep the corrugated look, or switch?

If the corrugated look is part of the building's character, like a restaurant, venue or older storefront, we install new corrugated panels in 24 or 26 gauge so you keep that look. Repair, coating and retrofit stay on the table when the existing sheets are still sound. If the building just needs to stay dry and the look does not matter, PBR or standing seam usually handles North Texas weather better: taller ribs carry more water at low slopes, and standing seam hides its fasteners. Our standing seam and PBR are 24 or 26 gauge, formed on our own roll formers to the length of each run, so long runs have no end laps.

Gauge matters more on corrugated

Corrugated sheet is sold in a wide range of thicknesses, and the thin, low-cost sheets common at big-box stores dent and crease easily. New corrugated we install is 24 or 26 gauge, and that gauge is written on the quote. See 26 vs. 24 gauge.

After a storm

We separate cosmetic dents from damage that lets water in and document both. We document the damage with photos and measurements and can be on the roof when your adjuster inspects. We don't adjust or negotiate claims; you work the claim with your insurance company. Texas law requires you to pay your deductible, and we never waive or rebate it.

We're certified with GAF, CertainTeed, Owens Corning, Atlas, Johns Manville, Carlisle, Tropical Roofing Products, Mule-Hide and Enviroshake. We offer same-day response in almost every case, and we answer leak and storm calls 24/7 at (817) 733-9228.

Related: commercial R-panel · commercial metal roofing · warehouses · metal roofing

Commercial warranty: a workmanship warranty from 10 years up to lifetime, depending on the job, plus both 10-year and 20-year NDL (no-dollar-limit) manufacturer warranties (the price depends on which NDL term you choose). Manufacturer coverage depends on the product and brand, and on the project qualifying for that manufacturer's program. We put the exact warranty for your roof in writing.

Certified, with 30 years installing every major roofing brand, a family roofing business going back 75 years, and over $80 million in completed roofing projects. 5.0 stars on Google at all three of our offices.

Request a free inspection or call (817) 733-9228. Small repairs are welcome too.

Frequently asked questions

Do you install new corrugated metal panels?

Yes. We install new corrugated panels in 24 or 26 gauge. We also repair, coat and retrofit existing corrugated roofs, or switch the building to PBR or standing seam when that fits better.

Is corrugated metal good for a commercial roof?

It can be, on slopes the panel is rated for and with good fastening. On low slopes, taller-rib PBR or standing seam usually performs better.

What is the minimum slope for corrugated metal roofing?

It varies by panel. Some publish 1:12 with sealant at every lap, and manufacturers commonly recommend 3:12 or steeper. We check the exact panel.

Can you fix a leaking corrugated roof without replacing it?

Often. New fasteners, sealed laps and new closures stop many leaks, and a restoration coating can extend sound sheets.

Can a new metal roof go over old corrugated?

Often, with a retrofit frame fastened to the structure below. We check the structure first.

Should we replace corrugated with PBR or standing seam?

Only if you want a different profile. If the corrugated look matters, we install new corrugated. If the building just needs to stay dry on a low slope, PBR or standing seam often performs better.

What gauge do you install?

24 or 26 gauge on new corrugated installs.