How it works
Wet insulation holds heat longer than dry insulation. On a sunny day the whole roof warms up; after sunset the dry areas cool off quickly while the wet ones stay warm. A thermal camera sees that difference. The published standard practice for this is ASTM C1153, for locating wet insulation in roofing systems with infrared imaging.
- Daytime visit: we walk the roof, note patches, curbs, drains and equipment, and check that the surface is dry
- Evening scan: a drone thermal pass after sunset, once the roof starts giving off its stored heat
- Mark and map: suspect areas are outlined on a roof plan
- Confirm: core cuts or moisture-meter readings in suspect and dry-looking areas, patched the same day
- Report: photos, thermal images and the wet areas on the plan. Every inspection comes with a free digital photo report, so you see what we see.
When infrared works, and when it doesn't
| Works well | Harder or unreliable |
|---|---|
| Flat and low-slope roofs with absorbent insulation or cover board under the membrane | Insulation that doesn't hold water, which gives little thermal signal |
| A sunny day followed by a clear, calm evening | A wet surface after rain, heavy cloud cover, or a windy night |
| TPO, PVC, EPDM, mod bit, smooth built-up and many coated roofs | Heavy gravel ballast, or a fresh coating that changes how the surface gives off heat |
| Finding the extent of a known leak | Metal roofs over open purlins, with no insulation layer to hold water |
Infrared shows temperature differences, not water. Rooftop units, extra layers of membrane, patches and fastener patterns can all look like moisture, which is why we confirm before anyone prices a tear-off.
What the results decide
| What the survey shows | Usual next step |
|---|---|
| Small wet areas near details | Cut out and replace the wet insulation, repair the source |
| Mostly dry roof, aging surface | A silicone, acrylic or urethane coating after wet areas are replaced |
| Wet areas over a large share of the roof | Tear-off and a new TPO, PVC or mod bit system |
| After a hailstorm | Documentation of where water got in, for you and your adjuster |
Under the 2021 IBC reroofing rules (Section 1512), a new roof generally can't be laid over an existing roof that is water-soaked or deteriorated, or over one that already has two or more layers. A moisture survey and a core cut tell us which applies. Coating over wet insulation traps the water, so we don't do it.
Questions to ask any infrared provider
- Will the scan be done after sunset, on a dry roof, after a sunny day?
- Will suspect areas be confirmed with cores or a meter, and patched the same day?
- Will the wet areas be shown on a roof plan you keep?
- Does the report separate "confirmed wet" from "suspect"?
Code sections and test standards are summarized in plain English from the published documents. Your building official, the manufacturer's current specification and the warranty document have the final word.
We're certified with GAF, CertainTeed, Owens Corning, Atlas, Johns Manville, Carlisle, Tropical Roofing Products, Mule-Hide and Enviroshake, and many other roof manufacturers. Our workmanship warranty runs from 10 years up to lifetime, depending on the job.
Commercial warranty: a workmanship warranty from 10 years up to lifetime, depending on the job, plus both 10-year and 20-year NDL (no-dollar-limit) manufacturer warranties (the price depends on which NDL term you choose). Manufacturer coverage depends on the product and brand, and on the project qualifying for that manufacturer's program. We put the exact warranty for your roof in writing.
Certified, with 30 years installing every major roofing brand, a family roofing business going back 75 years, and over $80 million in completed roofing projects. 5.0 stars on Google at all three of our offices.
Request a free inspection or call (817) 733-9228. Small repairs are welcome too.