Johns Manville PVC with Elvaloy KEE vs. JM PVC FB in Decatur: Smooth or Fleece-Backed for Your Commercial Roof?

By Blake Snow, owner ·

Illustration of a light gray PVC membrane roof with rooftop HVAC units on a brick commercial building
Illustration

Brands in this article

  • Johns Manville logo

Decatur and the rest of Wise County have a real mix of low-slope roofs: brick buildings around the courthouse square, metal and block buildings along US 287 and US 380, churches, schools, shops, restaurants and offices. A lot of them still have an old built-up or modified bitumen roof up top. When a bid lands on Johns Manville PVC, there’s one choice most proposals never explain: smooth JM PVC with Elvaloy KEE, or fleece-backed JM PVC FB?

I’m Blake Snow. I’ve been roofing for 30 years, we have an office right here in Decatur, and we’re certified with Johns Manville. This post is about choosing between JM’s two KEE PVC sheets. If you want to know how JM’s Peak Advantage guarantee works, what it excludes and how transfers work, read my Johns Manville guarantee post instead. I won’t repeat it here.

The short answer

  • Full tear-off to the deck, new insulation and cover board: smooth JM PVC with Elvaloy KEE is usually the simpler sheet, with more widths and thicknesses to pick from.
  • Covering a dry, sound built-up or mod-bit roof that’s allowed to stay, or a rough deck, or you want it set in hot asphalt or foam adhesive: JM PVC FB is usually the right sheet.
  • Same core membrane. Both use Dow Elvaloy KEE polymer, a non-wicking polyester scrim and JM’s aramid-reinforced edge. The fleece back is the difference.

What JM says about both sheets

From JM’s PVC roofing systems page and its product pages for JM PVC with Elvaloy KEE and JM PVC FB with Elvaloy KEE:

  • Elvaloy KEE (Ketone Ethylene Ester) polymer: JM uses it to keep plasticizer in the sheet, extend roof life and cut maintenance. JM’s FB data sheets say the membrane exceeded 40,000 hours of accelerated weathering testing, where ASTM G154 requires 5,000.
  • Aramid-reinforced edge: aramid fiber is woven into the fastening side of the sheet.
  • Non-wicking polyester scrim: JM says that because the edge doesn’t wick, edge sealant isn’t required.
  • Chemical resistance: JM says its PVC is inherently resistant to oils, air conditioning coolants, fuels and grease.
  • Standard: both meet ASTM D4434, Type III.

JM also makes JM PVC SD Plus and SD Plus FB. Those are a different PVC line. If your bid says “JM PVC,” ask which one.

Side by side

JM PVC with Elvaloy KEE (smooth)JM PVC FB with Elvaloy KEE
Back of sheetSmooth3.8 oz. spunbond polyester fleece
Thicknesses50, 60, 80 mil; 60 and 72 mil MIN60 mil, 60 mil MIN, 72 mil MIN, 80 mil
Roll widths (60 mil)3.25’, 5’, 6.5’, 10’ and 12’ (12’ white only, call for availability)6.33’ and 12’
Roll length (60 mil)100’90’
AttachmentAdhered or mechanically fastened, hot-air weldedAdhered, mechanically fastened, or hot asphalt (not 12’ width), hot-air welded
Over old BUR or SBSNot as a hot-asphalt cap sheetJM says it can be a cap sheet in BUR and SBS systems when adhered with hot asphalt
ColorsWhite, Grey, Grey ES, Charcoal, Sandstone, Sandstone ES (not every color stocked in every size)Same color family
White reflectance (60 mil, CRRC)0.86 initial / 0.70 after 3 years0.86 initial / 0.70 after 3 years
Peak Advantage term (60 mil, most JM PVC systems)Up to 25 yearsUp to 25 years

Sources: JM’s PVC selector guide (RS-8305), JM PVC 60 mil data sheet, JM PVC FB 60 mil data sheet and JM PVC FB 80 mil data sheet. JM notes that not every color or MIN sheet is stocked in every size, so minimums and lead times apply.

The big one: hot asphalt and old built-up roofs

This is where JM PVC FB earns its spot in Wise County. Plenty of buildings here have a built-up roof (felts and hot asphalt) or a modified bitumen roof that was put on decades ago.

JM’s FB data sheet says the sheet can be used as a cap sheet in BUR and SBS systems when adhered using hot asphalt. JM also publishes a “Hybrid Solutions” document on pairing its fleece-backed TPO and PVC with bituminous membranes. In plain terms, you can get a bright, welded PVC top surface on a roof that has asphalt plies underneath, which is something a smooth PVC sheet isn’t built to do.

A few details JM spells out:

  • The 12’-wide FB sheet isn’t for hot asphalt. Hot asphalt is the 6.33’ sheet.
  • JM’s 80-mil FB data sheet says hot asphalt with 12’ FB needs two hot installers to keep the asphalt warm enough to take the fleece. That’s one reason we match sheet width to the install method on every bid.

Can your existing roof stay? That’s decided on the roof, not on the phone:

  • It has to be dry. The building code doesn’t allow a recover over wet or deteriorated roofing, and no manufacturer wants its sheet over soaked insulation. We use moisture readings and core cuts, and our FAA-certified drone pilot can fly the roof first. See our drone roof inspection page.
  • There can’t already be too many roofs stacked up. If it’s been recovered before, it usually comes off.
  • Gravel has to be removed, and blisters, splits and soft spots fixed.

If those check out, JM PVC FB is how I’d put PVC on it. If not, we tear off, and you can use either sheet.

When smooth JM PVC with KEE is the better pick

  • Complete tear-off over new polyiso and a cover board. The fleece doesn’t buy you much over a clean new board, and the smooth sheet comes in more widths.
  • Mechanically fastened roofs on metal or wood decks, where you want fewer seams. The 10’ and 12’ smooth rolls cover a lot of roof.
  • Lots of small roof areas and details (penthouses, canopies, small additions), where narrow 3.25’ and 5’ rolls make the work cleaner.
  • Thicker smooth sheets. If you want 80 mil smooth, JM makes it in widths up to 12’.

Which sheet I’d use, building by building

Your Decatur or Wise County buildingWhat I’d usually specWhy
Restaurant with grease exhaust, full tear-offJM PVC with KEE, 60 or 80 milPVC handles grease; smooth sheet over new board
Older brick building with a dry built-up roof that can stayJM PVC FB in hot asphaltJM lists FB as a cap sheet over BUR
Mod-bit roof that’s dry and soundJM PVC FB, hot asphalt or approved adhesiveFleece takes the bond, PVC on top
Metal or block building, tear-off, mechanically fastenedJM PVC with KEE, 10’ or 12’ rollsFewer seams, quick install
Church or school with lots of roof areas and detailsJM PVC with KEE in mixed widthsNarrow rolls for small areas
Concrete deckJM PVC FB, adheredFleece handles the rough surface

These are starting points. The deck, the existing roof, the wind exposure and your budget decide the final spec. Some owners in Wise County also look at a modified bitumen replacement or a coating. Our TPO vs. modified vs. coating guide covers those trade-offs.

What to ask before you sign a JM PVC bid

  1. Is it JM PVC with Elvaloy KEE or JM PVC SD Plus?
  2. Smooth or FB? What thickness? Standard or MIN?
  3. Tear-off or recover? If recover, what did the moisture survey show, and how many roofs are on the building now?
  4. How is it attached: mechanically fastened, adhered (with what), or hot asphalt?
  5. What roll width, and does that width work with the install method?
  6. Is there a cover board? Which one?
  7. What color, and is it stocked in that size, or is there a minimum and a lead time?
  8. What warranty term, and is it NDL?
  9. Does the warranty include any hail or higher-wind riders? (See the guarantee post for how JM handles those.)
  10. Who pulls the permit, and who schedules the inspection?

Warranties on our JM PVC jobs

On commercial roofs we offer 10-year and 20-year NDL warranty options at different prices, and the bid spells out the membrane, thickness and attachment behind each one. Our workmanship warranty runs from 10 years up to lifetime, depending on the job.

After a storm

Get the roof inspected and documented before anyone patches it, and keep people off damaged areas. Our commercial hail claims page covers what to record. In Texas you generally have 1 year from the date of loss to file a claim, but check your policy.

Talk to us about a JM PVC roof in Decatur

We install Johns Manville PVC, TPO and modified bitumen on commercial buildings in Decatur, Bridgeport, Rhome, Boyd, Chico, Alvord, Paradise and across Wise County. We’re certified with GAF, CertainTeed, Owens Corning, Atlas, Johns Manville, Carlisle, Tropical Roofing Products, Mule-Hide and Enviroshake, and many other roof manufacturers. We’re fully insured, BBB A+ rated, and references are available on request.

See our Decatur commercial roofing and PVC roofing pages, use the estimate form below, or call (817) 733-9228.

Frequently asked questions

What's the difference between JM PVC with Elvaloy KEE and JM PVC FB?

Both are Johns Manville PVC membranes made with Dow Elvaloy KEE polymer, a polyester scrim and JM's aramid-reinforced edge, and both are hot-air welded at the seams. JM PVC with Elvaloy KEE is a smooth-backed sheet. JM PVC FB has a 3.8 oz. spunbond polyester fleece on the back, which JM describes as a durable protection layer. The fleece changes what the sheet can be adhered to and how.

Can JM PVC FB go over an old built-up or modified bitumen roof?

JM's data sheet says JM PVC FB can be used as a cap sheet in BUR and SBS systems when adhered using hot asphalt, and JM publishes 'Hybrid Solutions' using its fleece-backed PVC with bituminous membranes. Whether your existing roof can stay is a separate question: it has to be dry and sound, and the building code limits how many roofs can be stacked. We check with moisture readings and core cuts first.

What thicknesses do the two JM PVC sheets come in?

JM's PVC selector guide lists smooth JM PVC with Elvaloy KEE in 50, 60 and 80 mil, plus 60 and 72 mil MIN (minimum-thickness) versions. JM lists data sheets for JM PVC FB in 60 mil, 60 mil MIN, 72 mil MIN and 80 mil.

Which one is better for a restaurant in Decatur?

Either sheet uses the same KEE-based PVC, and JM says its PVC is inherently resistant to oils, air conditioning coolants, fuels and grease. On a full tear-off I usually lean smooth JM PVC with KEE. On a recover over an old asphalt roof, or over a rough deck, I lean JM PVC FB. The grease exhaust is handled by PVC either way; the existing roof decides smooth vs. fleece.

How long a guarantee can I get on JM PVC?

JM's 60-mil data sheets for both the smooth sheet and the FB sheet list Peak Advantage guarantee terms up to 25 years when used in most JM PVC systems. On our commercial bids we offer 10-year and 20-year NDL warranty options at different prices. Our workmanship warranty runs from 10 years up to lifetime, depending on the job.

Are you certified with Johns Manville?

Yes. We're certified with GAF, CertainTeed, Owens Corning, Atlas, Johns Manville, Carlisle, Tropical Roofing Products, Mule-Hide and Enviroshake, and many other roof manufacturers.

Hail hit our building in Decatur. How long do we have to file a claim?

In Texas it's generally 1 year from the date of loss, but check your policy. Have the roof inspected and documented before any repairs.