Carlisle Sure-Seal vs. Johns Manville EPDM for Denton Church and School Roofs: Thickness, Warranty Terms, Wind and Hail

By Blake Snow, owner ·

Illustration of a black EPDM rubber roof on a low-slope commercial building with rooftop vents and a metal parapet edge
Illustration

Brands in this article

  • Johns Manville logo
  • Carlisle logo

Carlisle Sure-Seal vs. Johns Manville EPDM is a choice Denton building committees and school facility managers run into when the bids come back and two roofers name two different rubber roofs, both promising “a 20-year warranty.”

I’m Blake Snow. I’ve been roofing for 30 years, and Snow Roofing & Exteriors is certified with both Carlisle and Johns Manville. Either one makes a good EPDM roof. What decides the right one for your building is the system: how thick the membrane is, how it’s attached, and what the warranty covers. This post compares Carlisle’s July 2026 EPDM specification with JM’s current Peak Advantage EPDM guarantee sheets so your committee or board can compare bids line by line.

The short answer

  • Both are NDL system warranties up to 30 years when built to the spec for that term.
  • Thickness rules are close. 60 mil gets you to 25 years adhered with either brand. 30 years takes 90 mil (or 75-mil reinforced).
  • Ballasted roofs can reach 30 years with both brands, if the structure can carry the ballast.
  • Hail coverage is built in, not added later. Carlisle ties hail to membrane thickness and a cover board set in adhesive. JM sells hail riders up to 3 inches with advance approval.
  • For occupied churches and schools, ask about low-VOC, water-based or self-adhered options and the schedule.

Side by side

Carlisle Sure-Seal / Sure-White / Sure-ToughJohns Manville EPDM
Warranty typeTotal System Warranty (membrane, flashings, adhesives, sealants and other Carlisle-brand products)JM Peak Advantage Guarantee; JM says all its single-ply guarantees are No Dollar Limit (NDL)
Terms5, 10, 15, 20, 25, 30 years5, 10, 15, 20, 25, 30 years
Adhered, 45 milCarlisle recommends 60 mil minimum non-reinforced; 45-mil Sure-Tough reinforced up to 15 yearsNon-reinforced 45 mil up to 15 years
Adhered, 60 milSure-Seal or Sure-White up to 25 yearsNR, FIT, FIT SA, R and white 60 mil up to 25 years
Adhered, 30 years90-mil Sure-Seal or Sure-White, or 75-mil Sure-Tough75-mil reinforced or 90 mil (incl. white 90)
Ballasted45-mil Sure-Seal up to 25 years; 60 mil up to 30; 90 mil 30 yearsNR 45 mil up to 15 years; 60 mil and thicker up to 30
Mechanically attachedSure-Tough reinforced: 45 mil up to 15, 60 mil up to 20, 75 mil 25 or 30Reinforced 60 mil up to 25 years; 75 mil up to 30
WindAdhered: 55 to 120 mph (SAT membranes max 100 mph). Ballasted: 55, 72 or 80 mphUp to 72 mph at no charge; riders 73 to 120 mph
HailAdhered non-reinforced: 1” (60 mil), 2” (90 mil), with cover board set in adhesive. Ballasted: 1” (45 mil), 2” (60 mil), 3” (90 mil). Reinforced adhered: 1” (60 mil), 2” (75 mil)Riders for 1, 1.5, 2, 2.5 and 3 inch hail, approved in advance
Accidental punctureSure-Tough reinforced: 8, 16 or 32 man-hours depending on termRiders for 8, 16 or 32 hours per year
Before the jobShop drawings submitted to Carlisle by the authorized applicator; 25/30-year jobs need Carlisle-approved shop drawingsApply at least 14 days before job start
After the jobCarlisle field service inspection decides whether the warranty is issuedJM inspects registered roofs; NDL issued within 6 months of substantial completion

Sources: Carlisle Sure-Seal / Sure-White / Sure-Tough EPDM specification, July 2026; JM Peak Advantage Guarantee Charges and Requirements, JM EPDM (RS-1670 6-25), rider sheet (RS-1691 10-25) and bulletin M25-003 (Feb. 10, 2025). Terms change, so we attach the current sheet to every proposal.

Adhered, ballasted or mechanically attached?

This decision usually matters more than the brand.

Adhered. The membrane is glued to the insulation or cover board. Carlisle says its adhered system has no maximum slope. It’s the go-to for buildings with a lot of edges, rooftop units and wind exposure, and it’s the route to the highest wind coverage with either brand. Carlisle’s hail coverage on adhered EPDM requires the cover board to be set in adhesive.

Ballasted. The membrane is laid loose and held down by stone or pavers. Carlisle’s spec calls for at least 10 pounds of ballast per square foot depending on wind load, and a maximum slope of 2 inches per foot. Many older school and church buildings in North Texas were built for ballast, and ballasted EPDM can still earn long terms with both brands. Carlisle shows its biggest hail number here: 3 inches with 90-mil membrane. The catch: the structure has to carry the weight, and Carlisle limits ballasted wind coverage to 80 mph.

Mechanically attached. Reinforced membrane fastened through to the deck at the seams. Carlisle uses Sure-Tough reinforced EPDM; JM uses reinforced 60 or 75 mil. It’s lighter and works on slopes up to 18 inches per foot in Carlisle’s spec, and Carlisle notes it can go over an existing standing seam, flat seam or corrugated metal roof in some cases. The wind coverage tops out lower than adhered with Carlisle (its reinforced table shows mechanically fastened at 55 to 90 mph).

Hail: decide it before the roof goes on

Denton gets hail. Neither brand treats hail as an afterthought, but they handle it differently:

  • Carlisle builds hail into the spec. On adhered non-reinforced EPDM: 1-inch coverage at 60 mil and 2-inch at 90 mil, each with the cover board set in adhesive. On ballasted roofs: 1 inch at 45 mil, 2 inches at 60 mil, 3 inches at 90 mil. On reinforced adhered membrane: 1 inch at 60 mil and 2 inches at 75 mil.
  • JM sells hail riders for 1, 1.5, 2, 2.5 and 3 inch hail. JM says every rider must be approved in advance by JM Technical Services.

If your church or district’s insurer cares about hail, put the hail size in the bid documents. Our commercial hail claims page covers what to document after a storm.

25- and 30-year terms: what changes

  • JM expanded its EPDM terms in February 2025: adhered 60-mil systems (reinforced, non-reinforced and FIT SA) became eligible for 25 years with 25-year details, adhered 75-mil reinforced for 30 years, and ballasted 60-mil non-reinforced for 30 years with 30-year details.
  • Carlisle’s 25/30-year design enhancements (July 2026) require all Carlisle-manufactured or -marketed products, complete removal of the existing roof on retrofit projects, and a final shop drawing approved by Carlisle before installation. Carlisle also recommends checking total R-value against the energy code because of the long term.
  • Re-covers and deck types limit terms with Carlisle. Its spec has separate tables for re-cover projects (up to 20 years), OSB decks (maximum 20 years), and lightweight concrete, gypsum and cementitious wood fiber decks (maximum 20 years).

So if a bid promises a 30-year Carlisle warranty on a re-cover over the old roof, ask for the table that allows it.

Churches and schools: occupied buildings

Most church and school roofs get replaced with people inside. A few things that help:

  • Adhesive choice. Carlisle lists Low-VOC and water-based bonding adhesives. Carlisle limits its water-based adhesive to 20-year warranties with wind coverage up to 72 mph. JM lists an LVOC membrane adhesive and an EPDM water-based membrane adhesive. Self-adhered membranes, Carlisle Sure-Seal SAT and JM EPDM FIT SA 60 mil, skip field adhesive. Carlisle caps SAT at 100 mph wind coverage.
  • Scheduling. We phase work around services, school days and events, and keep entrances and drop-off areas clear.
  • Rooftop traffic. HVAC techs walk these roofs. Carlisle’s spec calls for walkway protection where rooftop equipment needs regular maintenance (once a month or more). Put walkway pads in the bid.
  • Drainage. Carlisle’s spec says significant ponding that could remain after 48 hours should be eliminated with added drains, and recommends tapered edge strips, crickets or saddles where water may pond.

What a building committee or school board should see in the bid

Board and committee members aren’t roofers, and they shouldn’t have to be. Ask every bidder for:

  1. Manufacturer and exact system: brand, membrane name, thickness, reinforced or not, and attachment (adhered, ballasted or mechanically attached)
  2. The warranty: term, NDL, covered wind speed, hail size, puncture coverage, and the current guarantee sheet or spec table that allows it
  3. Insulation and cover board: product, thickness, and how it’s attached
  4. Tear-off or re-cover, and whether that limits the term
  5. Manufacturer steps: pre-job application or shop drawings, and the final manufacturer inspection
  6. Adhesive type and a phasing plan for an occupied building
  7. Walkway pads, edge metal, drains and flashings called out
  8. Workmanship warranty in writing

Public school districts in Texas also follow state rules for buying construction, including Texas Government Code Chapter 2269. We provide the documentation a district’s procurement process asks for. Churches have more flexibility, but the same side-by-side helps a committee explain its choice to the congregation.

Which one would I pick for a Denton church or school?

Either one, built right. Here’s how I’d sort it:

  • Older building already ballasted, structure confirmed: ballasted EPDM with either brand can reach 30 years; Carlisle lists 3-inch hail coverage at 90 mil.
  • Lots of edges, units and wind exposure: adhered EPDM with either brand. Compare Carlisle’s hail-by-thickness with JM’s hail riders.
  • Budget-driven 20-year roof with a tight schedule: compare Carlisle water-based or SAT options with JM FIT SA 60.
  • Thinking about 30 years: 90 mil or 75-mil reinforced, full tear-off with Carlisle, and the manufacturer’s approval before the job.

Not sure EPDM is the right roof at all? See our EPDM page, our manufacturer NDL warranty page, how to qualify for a 20-year NDL warranty, and my posts on Versico TPO and EPDM in Denton and Fort Worth, Holcim Elevate TPO and EPDM in Fort Worth and Johns Manville vs. Carlisle TPO warranties.

Permits and storms in Denton

We confirm the City of Denton’s current commercial permit requirements for your building and pull what’s required. After a storm, get the roof inspected and documented before anyone patches it, and keep people off damaged areas. Every inspection we do comes with a free digital photo report, with drone and thermal imaging. In Texas you generally have 1 year from the date of loss to file a claim, but check your policy. You can look up past storms for Denton County in NOAA’s Storm Events Database.

What goes on our EPDM proposals

  • Manufacturer, membrane, thickness and attachment, with the current spec table or guarantee sheet attached
  • Manufacturer NDL warranties on commercial roofs, typically 10 to 40 years, depending on the manufacturer, the system, and manufacturer approval
  • Wind speed, hail size and puncture coverage spelled out
  • Walkway pads, edge metal, drains and flashings called out
  • Manufacturer application and inspection steps on the schedule, plus closeout documents for the board or committee
  • Our workmanship warranty, from 10 years up to lifetime, depending on the job

Talk to us about an EPDM roof in Denton

We roof churches, schools and commercial buildings across Denton, Corinth, Argyle, Krum, Sanger and Lake Dallas. We’re certified with GAF, CertainTeed, Owens Corning, Atlas, Johns Manville, Carlisle, Tropical Roofing Products, Mule-Hide and Enviroshake, and many other roof manufacturers. We’re fully insured, BBB A+ rated, and have 5.0 stars on Google at all three offices: Bridgeport, Decatur and Rhome.

See our Denton church roofing, school roofing and Denton commercial roofing pages, use the estimate form below, or call (817) 733-9228.

Sources

Frequently asked questions

How thick does EPDM need to be for a 20- or 30-year warranty?

On adhered systems the two brands line up closely. Carlisle's July 2026 spec calls for 60-mil Sure-Seal or Sure-White for 5 to 25 years and 90 mil for 30 years (or 75-mil Sure-Tough reinforced for 25 and 30). JM's EPDM guarantee chart allows 45 mil up to 15 years, 60 mil up to 25 years, and 75-mil reinforced or 90 mil up to 30 years.

Can a ballasted EPDM roof get a 30-year warranty?

With both brands, yes, if the building can carry the ballast. Carlisle's ballasted table shows 60-mil Sure-Seal or Sure-White for 25 or 30 years and 90 mil for 30 years with more hail coverage. JM's chart allows 60-mil and thicker EPDM ballasted up to 30 years. Carlisle's spec says ballast is at least 10 pounds per square foot depending on wind load, so the structure has to be checked.

Do Carlisle and JM EPDM warranties cover hail?

Carlisle's spec ties hail coverage to the build: on adhered non-reinforced EPDM, 1 inch for 60 mil and 2 inch for 90 mil with the cover board set in adhesive; on ballasted systems, 1 to 3 inches depending on thickness. JM sells hail riders for 1, 1.5, 2, 2.5 and 3 inch hail, approved in advance by JM Technical Services.

Which EPDM warranty covers more wind?

Both can reach 120 mph on the right system. Carlisle's adhered tables run from 55 to 120 mph (self-adhered SAT membranes are capped at 100 mph) and ballasted systems from 55 to 80 mph. JM's rider sheet lists wind coverage up to 72 mph at no charge and riders from 73 to 120 mph, approved in advance.

What's the best EPDM option for a church or school that stays open during the work?

Ask about adhesives and schedule. Carlisle lists Low-VOC and water-based bonding adhesives (water-based is limited to 20-year, 72 mph warranties), and JM lists LVOC and water-based membrane adhesives. Self-adhered membranes such as Carlisle Sure-Seal SAT and JM EPDM FIT SA 60 mil skip field adhesive altogether.

Hail damaged our church roof in Denton. Is that a warranty claim?

Usually it's an insurance claim, unless your warranty includes hail coverage. In Texas you generally have 1 year from the date of loss to file, but check your policy.