Carlisle Sure-Weld FleeceBACK TPO vs. JM TPO FB for Fort Worth Re-Covers and Adhered Re-Roofs

By Blake Snow, owner ·

Illustration of a roofing crew unrolling white fleece-back TPO membrane over an existing dark commercial flat roof at sunset
Illustration

Brands in this article

  • Johns Manville logo
  • Carlisle logo

Carlisle Sure-Weld FleeceBACK TPO vs. JM TPO FB is the comparison Fort Worth building owners end up making when the old roof is still on the building and two bids say “fleece-back TPO, re-cover” with two different brand names on them.

I’m Blake Snow. I’ve been roofing for 30 years, and Snow Roofing & Exteriors is certified with both Carlisle and Johns Manville. Both make a good fleece-back TPO. This post sticks to the fleece-back sheets themselves and how they go down on re-covers and adhered re-roofs. For the warranty fine print (wind speeds, exclusions, transfers), see my Johns Manville vs. Carlisle TPO warranties post. If you’re looking at PVC instead, see Carlisle Sure-Flex KEE HP vs. FleeceBACK and JM PVC vs. JM PVC FB.

The short answer

  • Same idea, different lineups. Both are scrim-reinforced TPO with a polyester fleece laminated to the back. Carlisle sells three builds (100, 115, 135 mil total). JM sells four (FB 115 and 135 for adhesive or fasteners, FB 150 and 175 with a heavier fleece for hot asphalt).
  • Carlisle’s re-cover path is low-rise foam. Its FleeceBACK spec glues the sheet with Flexible FAST adhesive, and its re-cover table goes up to 20 years.
  • JM gives you a hot-asphalt option. FB 150 and 175 are approved for hot asphalt application only, which matters on old built-up roofs.
  • For 25 or 30 years, plan on the thick sheet. Carlisle FleeceBACK 135 or JM FB 135/175.
  • Hail coverage depends on the build. Carlisle ties it to sheet thickness and adhesive coverage. JM sells hail riders with advance approval.

Side by side

Carlisle Sure-Weld FleeceBACK TPOJM TPO FB
How it’s built45, 60 or 80-mil reinforced TPO laminated to a 55-mil polyester fleece60 or 80-mil reinforced TPO with an integral polyester fleece
SheetsFleeceBACK 100, 115, 135 (total thickness in mils)FB 115 (60 mil), FB 135 (80 mil), FB 150 (60 mil, heavy fleece), FB 175 (80 mil, heavy fleece)
Roll sizes12’ or 6’ wide; 50’, 75’ or 100’ long10’ wide; FB 115 100’ long, FB 150 75’, FB 135 and 175 50’
ColorsWhite, gray or tan; five special colors in 115 mil (limited stock); optional APEEL protective film on 115 white and 135 white/grayFB 115/135: white, with gray and tan special order. FB 150/175: white
AttachmentAdhered with two-part low-rise Flexible FAST adhesive (spray, extrusion or splatter), or mechanically fastened; RapidLock (hook-and-loop) optionFB 115/135: adhered or mechanically fastened. FB 150/175: hot asphalt only
SeamsHot-air welded, at least 1-1/2” wideHot-air welded
Warranty terms (adhered)100 mil up to 15 years; 115 mil up to 20; 135 mil up to 25 or 30FB 115: 5 to 20 years. FB 135: 5 to 30. FB 150: 15 or 20. FB 175: 15 to 30
Re-cover limitRe-cover table up to 20 years; 25/30-year tables are new construction or tear-offNot every JM spec is eligible for every term; JM confirms per job
Hail100 mil: 1” or 2”. 115 mil: up to 3”. 135 mil: 1”, 2” or 3”. 2” on 100 mil and 3” on 115 mil need full-coverage adhesive or beads 4” apartHail riders 1” to 3”, approved in advance
Dynamic puncture (maker’s test, ASTM D5635)20 J (100), 25 J (115), 32.5 J (135)27.5 J (FB 115), 35 J (FB 135)
Before and afterShop drawings submitted by the Carlisle Authorized Applicator; Carlisle field inspection decides whether the warranty is issuedApply at least 14 days before the job; JM inspects registered roofs; NDL issued within 6 months of substantial completion

Sources: Carlisle FleeceBACK Adhered Roofing System specification, July 2026 and FleeceBACK TPO product data sheet (10.02.25); JM data sheets for FB 115, FB 135, FB 150 and FB 175, and the JM Peak Advantage TPO guarantee sheet (RS-1668 9-26). Puncture numbers are each maker’s own test results, so treat them as a guide, not a head-to-head. Terms change, so we attach the current sheet to every proposal.

Why fleece-back is the re-cover sheet

On a re-cover, the new membrane goes over whatever is already up there: an old built-up roof, a granulated mod-bit cap sheet, or a tired single-ply. A smooth TPO sheet usually needs a cover board or slip sheet between it and that old surface. The fleece gives the adhesive something to grab, adds a cushion against what’s underneath, and adds puncture resistance.

Carlisle’s data sheet says its 115-mil FleeceBACK has 33% more puncture resistance and breaking strength than 60-mil TPO, and that FleeceBACK TPO passes FM’s severe hail test and UL 2218 Class 4. It also calls out low noise, low odor and no VOCs during install, which helps on occupied buildings like offices, clinics and restaurants. JM points to the fleece giving “more flexibility in varying substrates.”

Before anyone says “re-cover”: check the old roof

A re-cover only works on a roof that can take one. Here’s what we check on a Fort Worth building before we bid it:

  1. Moisture. Every inspection we do comes with a free digital photo report, with drone and thermal imaging. Wet spots get core cuts. Carlisle’s spec says wet insulation and membrane must be removed, with the voids filled with compatible material.
  2. How many roofs are already there. The building code limits re-covers, and a roof that’s already been re-covered usually has to come off. We confirm current City of Fort Worth requirements and pull the permit.
  3. What the old surface is. Carlisle’s re-cover table covers smooth or mineral-surfaced built-up and mod-bit, gravel built-up and coal tar pitch, and existing EPDM, TPO or Hypalon, each with its own adhesive bead spacing. Two catches in Carlisle’s spec: Flexible FAST is not approved over smooth APP modified bitumen, and loose gravel has to come off a gravel built-up roof.
  4. Old PVC. Carlisle says existing non-reinforced PVC must be removed (or cut into sections no larger than 10’ by 10’ with the new underlayment fastened), and old flashings come off.
  5. Venting the old roof. If there’s no vapor retarder, Carlisle recommends perforating the existing membrane, about one 3/4” hole every 100 square feet, so trapped moisture can be found later.
  6. Drains and ponding. A re-cover doesn’t fix bad drainage. Carlisle’s spec says ponding that stays after 48 hours should be fixed with added drains, and recommends crickets or tapered edge strips where water sits.

Adhered re-roof: low-rise foam vs. hot asphalt

Carlisle adheres FleeceBACK TPO with Flexible FAST, a two-part low-rise foam. It can be sprayed, extruded in beads or splattered, then the sheet is rolled in with a weighted roller. The bead spacing tightens with the term and wind speed: Carlisle’s table goes from 12-inch beads in the field for a 15-year, 55-mph warranty down to 4-inch beads in all roof zones for 30 years. Splatter at 50% coverage doesn’t qualify for the added hail or puncture coverage. Carlisle also limits HydroBond adhesive to 20-year, 90-mph warranties and Aqua Base 120 to 20-year, 72-mph warranties.

JM gives you two routes. FB 115 and 135 go down with adhesive: JM’s guarantee sheet lists JM QuickFoam Adhesive, JM Roofing System Urethane Adhesive (RSUA) and JM Two-Part Urethane Insulation Adhesive for fleece-back sheets. FB 150 and 175 have a heavier fleece built for hot asphalt, and JM says they’re approved for hot asphalt application only. If you own an older Fort Worth warehouse with a sound built-up roof and want a hot-mopped install, that’s the JM sheet built for it.

Which is better? It depends on the building. Hot asphalt means kettles and fumes on site. Low-rise foam is quieter and lower-odor. We’ll tell you which fits your building and your tenants.

Warranty terms: where the thick sheet matters

  • Carlisle: 100-mil FleeceBACK TPO up to 15 years, 115 mil up to 20, 135 mil for 25 or 30. Carlisle’s re-cover table tops out at 20 years; its 25- and 30-year tables are written for new construction or re-roofs with tear-off. Carlisle limits mechanically fastened FleeceBACK to 72-mph wind coverage.
  • JM: FB 115 for 5 to 20 years, FB 135 for 5 to 30, FB 150 for 15 or 20, FB 175 for 15 to 30. JM says not every specification is eligible for every term, every guaranteed job must be applied for at least 14 days before work starts, and all its single-ply guarantees are No Dollar Limit (NDL).

So if a bid promises 30 years on a re-cover, ask which table or guarantee approval allows it.

Hail and puncture in Fort Worth

Fort Worth gets hail. Carlisle’s FleeceBACK table offers added hail coverage by thickness: 1 or 2 inches on 100 mil, up to 3 inches on 115 mil, and 1, 2 or 3 inches on 135 mil. The 2-inch option on 100 mil and the 3-inch option on 115 mil require Flexible FAST in full coverage or beads 4 inches apart. Carlisle’s accidental puncture coverage runs 8, 16 or 32 man-hours per year depending on the sheet. JM sells hail riders for 1, 1.5, 2, 2.5 and 3-inch hail, each approved in advance by JM Technical Services, per its rider sheet.

If your insurer or lender cares about hail, put the hail size in the bid. My Carlisle Sure-Weld TPO hail and warranty post covers smooth-back Sure-Weld, and our commercial hail claims page covers what to document after a storm.

Which one would I use, building by building?

  • Older warehouse with a sound, dry built-up roof, owner wants hot-mopped: JM TPO FB 150 or 175 in hot asphalt.
  • Occupied office, clinic or retail center, re-cover over mod-bit or old single-ply: fleece-back in low-rise foam with either brand. Check the old surface against the adhesive approvals first.
  • Re-cover with a 20-year target: Carlisle FleeceBACK 115 or JM FB 115, if the existing roof qualifies.
  • Tear-off and 25 or 30 years: Carlisle FleeceBACK 135 or JM FB 135/175, with the manufacturer’s approval before the job.
  • Lots of rooftop traffic or hail exposure: step up to the thicker sheet and spell out puncture and hail coverage.

What to ask before you sign a fleece-back TPO bid

  1. Brand and exact sheet (FleeceBACK 100/115/135 or JM FB 115/135/150/175), color and roll width
  2. Re-cover or tear-off, and the moisture survey or core results behind that call
  3. What’s being removed: wet insulation, loose gravel, old PVC, old flashings
  4. Attachment: adhesive name and bead spacing, hot asphalt, or fasteners
  5. Cover board or underlayment, if any, and how it’s attached
  6. Warranty term, wind speed, hail size and puncture coverage, and the spec table or guarantee approval that allows it
  7. Manufacturer steps: shop drawings or pre-job application, and the final inspection
  8. Edge metal, drains, crickets, walkway pads and flashings called out
  9. Workmanship warranty in writing

What goes on our fleece-back TPO proposals

  • Manufacturer, sheet, color and attachment, with the current spec table or guarantee sheet attached
  • Manufacturer NDL warranties on commercial roofs, typically 10 to 40 years, depending on the manufacturer, the system, and manufacturer approval
  • Wind speed, hail size and puncture coverage spelled out
  • Moisture survey results and what’s being removed
  • Our workmanship warranty, from 10 years up to lifetime, depending on the job

After a storm

Get the roof inspected and documented before anyone patches it. In Texas you generally have 1 year from the date of loss to file a claim, but check your policy. You can look up past storms for Tarrant County in NOAA’s Storm Events Database.

Talk to us about a fleece-back TPO roof in Fort Worth

We roof warehouses, strip centers, churches and offices across Fort Worth, Haltom City, Saginaw, Benbrook, Keller and Southlake. We’re certified with GAF, CertainTeed, Owens Corning, Atlas, Johns Manville, Carlisle, Tropical Roofing Products, Mule-Hide and Enviroshake, and many other roof manufacturers. We’re fully insured, BBB A+ rated, and have 5.0 stars on Google at all three offices: Bridgeport, Decatur and Rhome.

See our TPO roofing, Fort Worth commercial roofing and Johns Manville contractor pages, use the estimate form below, or call (817) 733-9228.

Sources

Frequently asked questions

Can fleece-back TPO go over my existing roof in Fort Worth?

Often, yes, if the existing roof and deck are sound and the insulation is dry. Carlisle's July 2026 FleeceBACK spec has a re-cover table for smooth or mineral-surfaced built-up and modified bitumen roofs, gravel built-up and coal tar pitch (loose gravel removed), and existing EPDM, TPO or Hypalon. Wet insulation has to come out first, and the building code limits how many roofs can be stacked on a building, so we check both before we bid a re-cover.

What warranty can I get on a fleece-back TPO re-cover?

With Carlisle, the FleeceBACK adhered re-cover table goes up to 20 years; the 25- and 30-year tables are for new construction or re-roofs with tear-off. JM lists JM TPO FB 115 for 5 to 20 years and FB 135 for 5 to 30 years, but not every JM specification is eligible for every term, so JM's Guarantee Services confirms it on each job before it starts.

What's the difference between JM TPO FB 115/135 and FB 150/175?

JM TPO FB 115 and 135 (60- and 80-mil TPO with a fleece back) go down with adhesive or mechanical fasteners. FB 150 and 175 have a heavier fleece and JM says they are approved for hot asphalt application only. That's the sheet JM pairs with a hot-mopped install over an old built-up roof.

Is fleece-back TPO better in hail?

The fleece adds toughness. Carlisle says FleeceBACK TPO passes FM's severe hail test and UL 2218 Class 4, and its spec offers 1, 2 or 3-inch hail coverage depending on sheet thickness and adhesive coverage. JM sells hail riders up to 3 inches, approved in advance. No membrane is hail-proof, so put the hail size you want in the bid.

Which adhesive is used on fleece-back TPO?

Carlisle uses its two-part low-rise Flexible FAST adhesive, sprayed, extruded or splattered, and limits HydroBond and Aqua Base 120 adhesives to shorter terms. JM's TPO guarantee sheet lists JM QuickFoam Adhesive, JM Roofing System Urethane Adhesive and JM Two-Part Urethane Insulation Adhesive for fleece-back sheets, plus hot asphalt for FB 150 and 175.

Hail damaged our building's roof. Is that a warranty claim?

Usually it's an insurance claim, unless your warranty includes hail coverage. In Texas you generally have 1 year from the date of loss to file, but check your policy.