Snow Roofing & Exteriors logo Call (817) 733-9228
Blog

Tropical Roofing Products (SOPREMA) Silicone Coatings on Fort Worth Commercial Roofs: Substrate Prep, Primers, Recoats, Ponding and Heat

By Blake Snow, owner ·

Illustration of a roofer in a hard hat spraying white silicone coating over a gray flat commercial roof
Illustration

Fort Worth has miles of low-slope roofs that are tired but not finished: metal warehouses up the I-35W and Alliance corridor, strip centers on the west and south sides, older spray foam offices, and single-ply roofs on schools and churches. For a lot of them, a silicone restoration coating is worth pricing before a tear-off. If you’re comparing bids, you’ll likely see Tropical Roofing Products (TRP), now sold as SOPREMA.

I’m Blake Snow. I’ve been roofing for 30 years, and we’re certified with Tropical Roofing Products. I already covered the brand change, the 924 vs. 923 lineup and the warranty thickness chart in my Tropical Roofing Products coatings post for Frisco, so I won’t repeat that here. This post is about the job itself on Fort Worth roofs: what each roof type needs before the silicone goes on, using SOPREMA’s own data sheet, brochure and code approval.

The short answer

  • Metal buildings: clean, fix fasteners and seams with silicone mastic, prime rusted areas with 997, then coat. Plan on 15% to 40% more coating for the panel profile.
  • Aged single-ply (EPDM, PVC, TPO): clean and run adhesion tests. SOPREMA calls 924 primeless over most substrates, but the test decides.
  • Mod bit and built-up roofs: don’t pressure wash, use 996 bleed blocker as SOPREMA requires, and the finish has to be white.
  • Old silicone roofs: clean well and recoat with silicone. 924 is made to go over existing silicone.
  • Spray foam: 924 goes directly over properly prepared foam.
  • Never on shingles, tile, slate, wood shakes or metal shingles. SOPREMA’s code approval rules those out.

The names you’ll see on a Fort Worth bid

The TRP-to-SOPREMA switch means pails and paperwork can carry more than one name. Miami-Dade County’s current Notice of Acceptance for the Eterna-Sil series (NOA 25-0917.16, approved November 27, 2025, expires September 6, 2028) lists the products in pairs:

Older TRP / Eterna-Sil nameName listed with itWhat it is
924 Eterna-Sil Premium Roof CoatingALSAN COATING SIL 402Solvent-free, high-solids, one-part moisture-cured silicone coating
9400 Eterna-Sil Premium MasticALSAN COATING SIL 402 FlashingSolvent-free silicone mastic and seam sealer
997 Universal Acrylic & Silicone PrimerALSAN COATING Universal PrimerWater-based primer (rust-inhibiting over metal, per SOPREMA’s brochure)
996 Asphalt Bleed BlockerALSAN COATING Asphalt Bleed Blocking PrimerWater-based acrylic primer that blocks asphalt bleed-through
923 Eterna-Sil Roof Coating(no second name listed)Solvent-based silicone coating
Rx Roof Repair(no second name listed)Fibered silicone repair mastic

One more naming note: Tropi-Cool is a silicone coating name from a different manufacturer, not TRP. Nothing wrong with it, but it has its own data sheet and warranty, so don’t assume a “Tropi-Cool” bid is a Tropical Roofing Products bid.

Substrate by substrate: what SOPREMA calls for

These steps come from SOPREMA’s 924 product data sheet, its silicone and acrylic coatings brochure, and the Miami-Dade NOA. SOPREMA also points installers to its Roof Coatings Technical Manual for complete instructions.

Fort Worth roofCleanPrime / sealRepairs before coating
Galvalume or galvanized metal652 UltraGreen cleaner (10:1)Direct to galvanized steel is an approved option; 997 is the other optionFasteners and seams with 9400 Eterna-Sil Premium Mastic; replace stripped screws
Aluminum panelsClean per SOPREMA997 primer required first (per the NOA), fully cured before coatingSame seam and fastener work
Surface-rusted metalClean, remove loose rust997 at 1.0 gal per 100 sq. ft. on rusted areasRusted-through panels get replaced, not coated
EPDMClean per SOPREMADirect, or 997 first (both are NOA options); adhesion test decidesSeams, laps and penetrations
PVC and aged TPOClean per SOPREMA924 is primeless over most substrates; adhesion test decidesSeams, laps and penetrations
Granulated mod bit or granulated BURNo pressure washing on asphalt roofs996 bleed blocker required for 924 unless Technical Services signs off; white finish onlyTwo coats of 996 over asphalt repairs
Smooth mod bit, smooth BUR, APPNo pressure washing996 required; white finish onlyTwo coats of 996 over asphalt repairs
Spray polyurethane foamPrepare per SOPREMA924 goes directly on properly prepared foamRepair damaged or degraded foam first
Existing silicone coatingClean thoroughlyGo directly over existing silicone after proper cleaningPatch with silicone (9400 or Rx Roof Repair)
Shingles, tile, slate, wood shakes, metal shingles—Not allowed (NOA general limitations)Different roof, different fix

A word on the NOA numbers: the Miami-Dade approval lists code minimums of 1.20 gallons per 100 sq. ft. (18 mils dry) for 924 on most substrates. Those are not warranty rates. SOPREMA’s warranty requires more coating for each term, and I laid out that chart in the Frisco post. If a Fort Worth bid quotes 1.2 gallons and promises a long warranty, ask which document it follows.

Metal buildings: where most Fort Worth coating jobs start

Metal shops, warehouses and ag buildings are the bread and butter of coating work around Fort Worth. What makes them succeed or fail:

  1. Fasteners. Back-out and stripped screws leak first. Tighten or replace with oversized fasteners, then encapsulate with silicone mastic. SOPREMA’s chart lists 9400 Eterna-Sil Premium Mastic at about 85 to 125 linear feet per gallon in a 4-inch-wide application.
  2. Laps and seams. Seal them with mastic (and reinforcing fabric where specified) before the field coat.
  3. Rust. Surface rust gets cleaned and primed with 997, which SOPREMA describes as rust-inhibiting over metal. Panels that are rusted through get replaced. We run our own roll formers for 24- and 26-gauge R-panel and standing seam, and offer PBR and corrugated panels, with a typical lead time of 1 to 2 weeks.
  4. Profile factor. SOPREMA says to add a surface factor for the metal profile, normally 15% to 40%. A bid that uses flat-roof gallons on a ribbed roof will end up thin.

More on metal in our metal roof coating page.

Recoating an old silicone roof

Plenty of Fort Worth buildings were coated with silicone 10 or 15 years ago and are due again. The good news: SOPREMA says 924 is recoatable over itself and existing silicone, and its coverage chart says to go directly over an existing silicone-coated system once it’s been properly cleaned.

In practice, almost nothing but silicone sticks well to cured silicone, so an old silicone roof gets recoated with silicone. What we do on those jobs:

  • Clean hard. Old silicone holds dirt, which is a big reason it loses brightness. We clean to SOPREMA’s procedure and let the roof dry fully.
  • Adhesion test patches. SOPREMA advises peel tests before application. On recoats it tells you whether the old film is still well bonded.
  • Find the failures underneath. Peeling or blistered areas usually mean wet insulation or a bad bond below. Those get cut out and repaired, not buried.
  • Moisture survey. We look for wet insulation before quoting. Our drone roof inspection includes thermal imaging.

Ponding water on flat Fort Worth roofs

SOPREMA describes 924 as having resistance to ponding water, which is a real advantage of silicone over acrylic. But a coating isn’t a drainage fix, and SOPREMA’s warranty excludes leaks from lack of slope or poor drainage (details in the Frisco post). On Fort Worth strip centers and warehouses, the usual culprits are clogged scuppers, sagging deck sections and HVAC curbs that dam water. We clear drains and add crickets or tapered insulation where water sits for days. For an emergency patch, SOPREMA’s Rx Roof Repair is made to adhere to wet and dry surfaces, though SOPREMA says standing water should be removed first.

Heat, storms and storage: the Fort Worth part

SOPREMA’s 924 data sheet sets the limits:

  • Don’t apply below 40°F, and don’t apply if rain is forecast during application or within one hour after. In spring storm season, that one-hour window matters.
  • The surface must be clean and dry, on and beneath the surface. After a storm, a roof that looks dry can still hold water under the membrane.
  • Store between 50°F and 80°F. Don’t heat the container, and never use coating that has frozen. In a Fort Worth August, that means shaded or climate-controlled storage, not pails sitting on a hot roof or in a closed trailer.
  • Don’t thin it, and use airless spray equipment with moisture-resistant components, since silicone cures with moisture.

On hot days we start early, keep material shaded, and check wet film with a gauge as we go.

When a coating is the wrong call

  • Wet insulation over large areas: coating traps it. That’s a tear-off or partial replacement.
  • Hail-fractured membrane or crushed insulation: document it first. A coating doesn’t repair hail damage. See our commercial hail claims page.
  • Shingle, tile or slate roofs: not eligible under SOPREMA’s approval.

More on the decision in our roof coating vs. replacement guide.

Questions to ask on a Fort Worth TRP / SOPREMA silicone bid

  1. Is the coating 924 Eterna-Sil Premium / ALSAN COATING SIL 402 or 923? Which label will be on the pails?
  2. What’s the substrate, and which primer (997, 996 or none) did the adhesion test call for?
  3. Will asphalt roofs be pressure washed? (SOPREMA says no.)
  4. How are fasteners, seams and penetrations handled, and with which mastic?
  5. What profile factor is in the gallons for a metal roof?
  6. Was a moisture survey done, and how will wet areas be repaired?
  7. How many gallons per 100 sq. ft., what dry mils, and which SOPREMA warranty form and term?
  8. How will material be stored in summer heat?

Comparing other silicone lines?

If you’re weighing more than one brand, see my Inland AldoSil 397 vs. 395 post (also Fort Worth), my Mule-Hide silicone vs. acrylic post, and our silicone roof coating page.

After a storm

Get the roof inspected and the damage documented before anyone coats it. Check Tarrant County storm history in the NOAA NCEI Storm Events Database. In Texas it’s generally 1 year from the date of loss to file a claim, but check your policy.

Talk to us about a silicone coating in Fort Worth

We coat and restore commercial roofs across Fort Worth, Haltom City, North Richland Hills, Saginaw, Haslet, White Settlement and Benbrook. We’re certified with GAF, CertainTeed, Owens Corning, Atlas, Johns Manville, Carlisle, Tropical Roofing Products, Mule-Hide and Enviroshake, and many other roof manufacturers. Commercial jobs can carry 10- and 20-year NDL warranties, and our workmanship warranty runs from 10 years up to lifetime, depending on the job. We’re fully insured, BBB A+ rated, and have 5.0 stars on Google at all three offices: Bridgeport, Decatur and Rhome.

See our commercial roof coatings page, spray foam roofing page and Fort Worth commercial roofing page, use the estimate form below, or call (817) 733-9228.

Sources

Frequently asked questions

Is ALSAN COATING SIL 402 the same as 924 Eterna-Sil Premium?

They're listed together. Miami-Dade County's Notice of Acceptance for the Eterna-Sil series (NOA 25-0917.16, approved November 27, 2025) lists '924 ETERNA-SIL PREMIUM ROOF COATING or ALSAN COATING SIL 402' as the same solvent-free, high-solids silicone coating, and pairs 997 Universal Primer with ALSAN COATING Universal Primer and 996 Asphalt Bleed Blocker with ALSAN COATING Asphalt Bleed Blocking Primer. Ask your contractor which label is on the pails and confirm the warranty spec with SOPREMA.

Is Tropi-Cool a Tropical Roofing Products coating?

No. Tropi-Cool is a silicone coating name sold by a different manufacturer. Tropical Roofing Products' silicones are the Eterna-Sil line (924 and 923), now sold under the SOPREMA brand. If a bid lists Tropi-Cool, it's a different product with its own data sheet and warranty.

Can you put 924 Eterna-Sil over an old silicone roof?

SOPREMA says 924 is recoatable over itself and existing silicone, and its coverage chart says to go directly over an existing silicone-coated system after it has been properly cleaned. We still do adhesion test patches first, because SOPREMA advises peel tests before any application.

Do you need a primer under 924 on a mod bit or built-up roof?

Usually yes. SOPREMA's brochure says 996 Asphalt Bleed Blocker is required under 924 over APP, smooth BUR, mineral cap sheets and SBS unless SOPREMA Technical Services signs off, that only white coatings are permitted over asphaltic roofs, and that remedial repairs to asphalt substrates need two coats of 996.

Can a silicone coating go on in a Fort Worth summer?

Yes, with planning. SOPREMA's 924 data sheet sets a minimum of 40°F and no rain forecast during application or within one hour after. It also says to store the coating between 50°F and 80°F and never use it if it has frozen. In July and August that means shaded or climate-controlled storage, not pails baking on the roof or in a trailer.

Does a silicone coating fix hail damage?

No. A coating protects a sound roof. It doesn't repair hail-fractured membrane, crushed insulation or dented metal, and coating over undocumented damage can complicate a claim. Get the roof inspected and documented first. In Texas it's generally 1 year from the date of loss to file a claim, but check your policy.

Get a free roof inspection

We get on the roof, photograph what we find, and tell you plainly whether you need a repair or a replacement.

Get a free estimate

Tell us how to reach you. Blake or the team will call you back.

Or call (817) 733-9228 snowexteriors@gmail.com